Quantcast
Channel: Dialogic PowerMedia HMP GlobalCall and R4 API - Recent Threads
Browsing all 1151 articles
Browse latest View live

RE: gc_OpenEx succeed but received GCEV_OPENEX_FAILevent

Ok, the reference to libuuid would have been noted in error seen in RTF logging on application startup as well. xx/xx/xxxx  09:04:45.336 3601 4151985872 libipm ERR1 dll Failed to load library...

View Article


Using mm_Capture() to take an image from a video call

Hi,I am trying to use mm_Capture() to take a photo from a SIP call. I am performing the following steps:Opening two ip media devices and the multimedia deviceUsing dev_PortConnect() to establish a full...

View Article


RE: gc_MakeCall for direct SIP calls

Not sure if this is what you want but take a look at this section from GC IP TUG:4.33 Dynamic Selection of Outbound SIP Proxywww.dialogic.com/.../13478.aspxJeff

View Article

RE: gc_MakeCall for direct SIP calls

No Jeff, as I said before, changing outbound proxy online is not an option cause as Dialogic doc says: "...The application can now configure (or reconfigure) the proxy address to use temporarily for...

View Article

RE: gc_MakeCall for direct SIP calls

Yes, you can if you create two separate IP_VIRTBOARDs. One for proxy, and the other for non proxy calls.Jeff

View Article


RE: gc_MakeCall for direct SIP calls

Yes, that works! Thanks!

View Article

gc_MakeCall for direct SIP calls

Hello,How to prepare proper settings for gc_MakeCall when making direct SIP call e.g.(to "sip:100@192.168.0.199") and there is no configured proxy or proxy is another server (e.g. 192.168.0.100 as...

View Article

RE: Using mm_Capture() to take an image from a video call

Hi Brendan,Could you please check if the transcoding is ON between the devices?Thanks,Sunil.

View Article


RE: ERROR - unexpected message

Hi Jeff,I'm facing the same with HMP 4.1.213[root@mgw1-test jinny]# cat /usr/dialogic/cfg/buildinfoDialogic(R) HMP Software Release LINSystem Release Build Date = 12/18/2015System Release Build Number...

View Article


Changing Contact Header in 200 OK response HMP

Hi,I have one question . When i receive incoming INVITE request uri is in format  tel:number  so HMP automaticly puts this in Contact header in 200 OK response . Is it possible to change  this Contact...

View Article

RE: Changing Contact Header in 200 OK response HMP

Refer to Section 4.9 Setting and Retrieving SIP header messages fields from the Global IP Tech Guide here:www.dialogic.com/.../globalcall_for_ip_hmp_v12.pdfJeff

View Article

RE: ERROR - unexpected message

Hi,As stated prior I had seen this type of error show up when host library sends commands down to firmware in an unexpected state. You would have to check the RTF log for any error, or what APIs may...

View Article

ERROR - unexpected message

Dear all,During my load testing on HMP 4.1, it found it has some repeated error messages under /var/log/messages.Do anyone has some idea on the root cause ?Aug  9 02:49:36 VMSPOC ssp_x86Linux_boot:...

View Article


RE: ERROR - unexpected message

Hi Jeff,Can you please help us identifying the root cause? I've uploaded the RTF log to the below...

View Article

RE: ERROR - unexpected message

Just to clarify is your app running in 3PCC mode?   I see some events in log which indicate that. Also, it seems there is a fair amount of INVITE being rejected with 603 Declined in this case. That...

View Article


RE: ERROR - unexpected message

Hi Jeff,Our application is running in 3PCC mode.The Status Code 603 is normal because it is generated by one of our application which is missed call alert.The amount of ERROR is very small comparing to...

View Article

RE: D/480 JCT - 2T1. Genload.exe: Power Requirement was not met for board in...

I am getting the same error, even after setting the jumper to 2-3.I am using a Lenovo System-x 3650 server with Windows 2012 R2. Using Dialogic version 6 Su 271.The PCIe slot is a 16x, 8x, 4x,1x slot...

View Article


D/480 JCT - 2T1. Genload.exe: Power Requirement was not met for board in slot...

We installed a dialogic card D/480 JCT - 2T1 on a HP server with Windows 2003 server OS. Dialogic driver software 6.0 was installed. The following error message showed in Event Viewer when we tried to...

View Article

RE: D/480 JCT - 2T1. Genload.exe: Power Requirement was not met for board in...

Hi,To be more specific since different products and errors were seen in the prior trail of this discussion. What exact board are used in this case? Are they detected correctly in the windows device...

View Article

RE: ERROR - unexpected message

From a quick check I see this showed up during a gc_dropcall (or around that time) and suspect that it has to due with handling of RTP steam via IPML. From other cases we had seen in the past, this...

View Article
Browsing all 1151 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>