Best way to find the end of voicemail greeting
Hello,I have tried several settings and will keep trying but thought I would throw this out there. What is the best way to detect the end of a voicemail/answering machine message in order to leave a...
View ArticleMultiple DNI boards give CT Bus error
Im trying to figure out a problem with server which has multiple DNI boards. The server has 2Â DNI1210TEPE2HMP boards and also the correct licensing for it. The problem is when starting the system the...
View ArticleRE: Multiple DNI boards give CT Bus error
Hi Espen,As a first step, check if you have connected the boards with sync route cable and set the termination jumpers on the boards. Please see "Setting CT Bus Termination" in...
View ArticleRE: Multiple DNI boards give CT Bus error
Hey SunilThere is no syncroute cable present in the server. Is the syncroute cable required for operating more than 1 DNI board in the same server? When reading the documentation it seems more like an...
View ArticleRE: Multiple DNI boards give CT Bus error
Hi Espen,It is required to use sync route cable when using more than one DNI board in the system. Please see section "5. Installing the Board" in www.dialogic.com/.../64-1122-03.pdf.I hope this...
View Articlesr_WaitThreadDeviceGroup() doesn't retrieve some events on HMP Linux
I have an application that makes use of the "thread device group" functionality in the Standard Runtime Library. After opening my primary board with gc_OpenEx(), I pass the line device id to...
View ArticleIPMEV_INIT_RECEIVED repeated when already received IPMEV_INIT_COMPLETE
Hi,I don't understand why IPME_INIT_RECEIVED repeated frequenly. This is my debug console, please help?ipm_InitSend successful for Nbup for device=ipmB1C1Received a non-GC Event...
View ArticleHMP with Call Script app (VoiceGuide): "488 hot acceptable here" error for...
Hello,We are using HMP with IVR app called VoiceGuide for our IVR solution.After upgrading the software VoiceGuide, we get "488 not acceptable here" error upon "re-INVITE."The call script used for this...
View ArticleRE: ipm_InitResponseSend raise IPMEV_ERROR
This is error in trflog10/29/2015 13:40:27.717  2045  2972117904 Dm3Odi.dll        Error     Qcd [0:1:1:5:1] CDm3StdComp::Dm3GetErrorResult() -> (Std_MsgError) Message[0x402b] Xid[0x7]...
View Articleipm_InitResponseSend raise IPMEV_ERROR
Hi,I used this function to send initResponseboolInitResponseSend (){IPM_INIT_RESPONSE initResp;IPM_NBUP_INIT_RESPONSE nbupResp;// Initialize the main structureINIT_IPM_INIT_RESPONSE...
View ArticleDialogic Diva PRI/E1-30 PCI card not compatible with HP Proliant Gen9 server
The drivers do not work, dialogic tech support have attempted to resolve but could not. They tried latest software release 8.5WIN Update 14A workaround using a generic mircosoft driver worked...
View ArticleHMP 4.0 BICC how to bridge 2 calls
Hi,My system dial to party A, and party B. After A answer and B answer, I want to bridge call between A and B for conversation between A and B. How can I do?I use BICC with IPM and MMThank you very much
View ArticleRE: Dialogic Diva PRI/E1-30 PCI card not compatible with HP Proliant Gen9 server
This wouldn't be the right forum for this post. Nevertheless, for installation issues like this we'd encourage you to work directly with the support team. We can confirm that we have not seen any...
View ArticleRE: HMP with Call Script app (VoiceGuide): "488 hot acceptable here" error...
Could someone reply? I am a bit desperate here.thanks.
View ArticleSDP on INVITE in 1pcc mode from HMP application
I have an HMP application that runs in 1pcc mode.I am unable to make outbound calls with a single major hosted PBX provider because they always reply "603 Decline".After much debugging at the hosted...
View ArticleRE: SDP on INVITE in 1pcc mode from HMP application
No, regrettably, in 1PCC the application does not have direct access to SDP. "i=" is a valid field, and HMP has no tuning to remove it.
View ArticleRE: HMP with Call Script app (VoiceGuide): "488 hot acceptable here" error...
The second Invite comes with G729 codec, which is probably not licensed on your system. Also, both offers come with 20 ms frame size, while the app sets 30 ms; I'd fix this first.
View Article